Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. cardiol ; 105(3): 248-255, Sept. 2015. tab
Article in English | LILACS | ID: lil-761508

ABSTRACT

AbstractBackground:Heart failure with preserved ejection fraction is a syndrome characterized by changes in diastolic function; it is more prevalent among the elderly, women, and individuals with systemic hypertension (SH) and diabetes mellitus. However, in its early stages, there are no signs of congestion and it is identified in tests by adverse remodeling, decreased exercise capacity and diastolic dysfunction.Objective:To compare doppler, echocardiographic (Echo), and cardiopulmonary exercise test (CPET) variables - ergospirometry variables - between two population samples: one of individuals in the early stage of this syndrome, and the other of healthy individuals.Methods:Twenty eight outpatients diagnosed with heart failure according to Framingham’s criteria, ejection fraction > 50% and diastolic dysfunction according to the european society of cardiology (ESC), and 24 healthy individuals underwent Echo and CPET.Results:The group of patients showed indexed atrial volume and left ventricular mass as well as E/E’ and ILAV/A´ ratios significantly higher, in addition to a significant reduction in peak oxygen consumption and increased VE/VCO2 slope, even having similar left ventricular sizes in comparison to those of the sample of healthy individuals.Conclusion:There are significant differences between the structural and functional variables analyzed by Echo and CPET when comparing two population samples: one of patients in the early stage of heart failure with ejection fraction greater than or equal to 50% and another of healthy individuals.


ResumoFundamento:Insuficiência cardíaca com fração de ejeção preservada é uma síndrome caracterizada por alterações da função diastólica mais prevalente em idosos, mulheres e portadores de hipertensão arterial sistêmica (HAS) e diabete melito. No início, entretanto, não revela sinais de congestão, identificando-se por remodelamento adverso, diminuição da capacidade de exercício e disfunção diastólica nos exames.Objetivo:Comparar variáveis ecocardiográficas e de doppler (Eco) e do teste cardiopulmonar de exercício (TCPE) - ergoespirométricas - entre duas amostras populacionais: indivíduos portadores dessa síndrome em estágio inicial e outra de saudáveis.Métodos:Vinte e oito pacientes ambulatoriais com diagnóstico de insuficiência cardíaca por critérios de Framingham, fração de ejeção > 50% e disfunção diastólica segundo a european society of cardiology (ESC), e 24 indivíduos saudáveis realizaram estudos de Eco e TCPE.Resultados:O grupo de pacientes apresentou volume atrial e massa ventricular esquerda indexadas, bem como as razões E/E’ e VAEi/A´ significativamente maiores, além de significativa redução do consumo máximo de oxigênio e incremento da inclinação da variável VE/VCO2, mesmo com semelhantes dimensões do ventrículo esquerdo, quando comparados à amostra dos saudáveis.Conclusão:Há diferenças significativas entre variáveis estruturais e funcionais analisadas nos estudos ao Eco e ao TCPE, comparando-se duas amostras populacionais: pacientes com estágio inicial de insuficiência cardíaca com fração de ejeção maior ou igual a 50% e outra de indivíduos saudáveis.


Subject(s)
Female , Humans , Male , Middle Aged , Exercise Test/methods , Heart Failure/physiopathology , Heart Failure , Stroke Volume/physiology , Case-Control Studies , Echocardiography, Doppler/methods , Observer Variation , Oxygen Consumption/physiology , Spirometry/methods , Time Factors , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left/physiology
2.
Arq. bras. cardiol ; 103(4): 299-307, 10/2014. tab, graf
Article in English | LILACS | ID: lil-725318

ABSTRACT

Background: The equations predicting maximal oxygen uptake (VO2max or peak) presently in use in cardiopulmonary exercise testing (CPET) softwares in Brazil have not been adequately validated. These equations are very important for the diagnostic capacity of this method. Objective: Build and validate a Brazilian Equation (BE) for prediction of VO2peak in comparison to the equation cited by Jones (JE) and the Wasserman algorithm (WA). Methods: Treadmill evaluation was performed on 3119 individuals with CPET (breath by breath). The construction group (CG) of the equation consisted of 2495 healthy participants. The other 624 individuals were allocated to the external validation group (EVG). At the BE (derived from a multivariate regression model), age, gender, body mass index (BMI) and physical activity level were considered. The same equation was also tested in the EVG. Dispersion graphs and Bland-Altman analyses were built. Results: In the CG, the mean age was 42.6 years, 51.5% were male, the average BMI was 27.2, and the physical activity distribution level was: 51.3% sedentary, 44.4% active and 4.3% athletes. An optimal correlation between the BE and the CPET measured VO2peak was observed (0.807). On the other hand, difference came up between the average VO2peak expected by the JE and WA and the CPET measured VO2peak, as well as the one gotten from the BE (p = 0.001). Conclusion: BE presents VO2peak values close to those directly measured by CPET, while Jones and Wasserman differ significantly from the real VO2peak. .


Fundamento: As equações que predizem o consumo máximo de oxigênio (leia-se VO2máx ou pico) utilizadas em softwares de teste cardiopulmonar de exercício (TCPE) no Brasil não foram validadas e têm importância fundamental no algoritmo diagnóstico desse exame. Objetivo: Construir e validar uma equação derivada de população brasileira (EB) para predição do VO2, comparando-a com a equação citada por Jones (EJ) e com o algoritmo de Wasserman (AW). Métodos: Foram avaliados, pelo TCPE, 3.119 indivíduos aparentemente saudáveis. Destes, 2.495 pertenceram ao grupo de construção (GC) e 624 foram alocados de forma aleatória no grupo de validação (GV). Na EB consideraram-se idade, gênero, índice de massa corporal (IMC) e nível de atividade física, sendo a mesma posteriormente testada no GV. Resultados: No GC, a idade média foi de 42,6 anos, 51,5% eram homens, o IMC médio foi de 27,2, sendo 51,3% sedentários, 44,4% ativos e 4,3% atletas. No GV não houve diferença entre o VO2pico médio medido pelo TCPE (29,92 mL.kg−1.min−1) e pela EB (29,80 mL.kg1.min−1/p = 0,571), sendo observada ótima correlação (0,898). O AW e a EJ tiveram valores médios diferentes do VO2pico medido (p <0,001). O percentual do erro total foi de 18%, 26% e 41% para EB, AW e EJ, respectivamente. A distribuição dos resíduos foi predominantemente negativa no AW (70,67%) e na EJ (87,66%), evidenciando que ambas superestimam os valores médios do VO2pico. Conclusão: A EB apresenta valores de VO2pico muito próximos do valor medido através do TCPE, enquanto o AW e a EJ diferem significativamente do VO2pico real. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Algorithms , Exercise Test/methods , Oxygen Consumption/physiology , Respiratory Function Tests/methods , Age Factors , Body Mass Index , Brazil , Predictive Value of Tests , Reference Values , Regression Analysis , Reproducibility of Results , Sex Factors , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL